Skip to content

CryoArc™ Deca -190°C LN2-Based Automated Storage System

The CryoArc Deca automated cryogenic preservation solution is ideal for sample management from discovery to clinicals. Built with best-in-class performance, Deca safeguards fragile cellular products and other temperature-sensitive biosamples along with comfortable user convenience.

  • For labs with medium sample collections including biobanks
  • Full, real-time inventory control with LIMS connectivity
  • Supports cold-chain management strategies
  • Rapid cryosample retrieval without ergonomic risks

Want to request a quote, or to contact an expert?

Product Details

Protect your precious cryogenic samples in up to 266 cryoboxes, 1520 25 mL cassettes, or 760 50 mL cassettes with the CryoArc Deca -190ºC LN2-Based Automated Storage System. This purpose-built automated cryogenic storage solution combines robust, documented sample integrity protection along with user-friendly sample management and control to ease your cryogenic sample storage workflows

The Deca consists of a familiar high-efficiency LN2 stainless steel freezer along with an insulating sample transport robotic tower, and powerfully intuitive CryoArc Software. Together, these combined components become an integral tool in your automated cell and biological sample management workflows.

The Sample Experience

Sample boxes from 1 to 7 inches tall or cassettes placed into the insulated robotic tower are automatically delivered to user specified or system optimized locations within the CryoArc Deca. Inventory information is tracked at the tube, cassette, and microplate level, and can be shared with your facility’s LIMS.

The liquid nitrogen vapor phase provides a consistent -190 ºC temperature for stored samples from top to bottom. In case of electrical outages, LN2 interruption, or other unforeseen hazards, Deca provides up to 15 days of temperature stability to protect samples from harm. An onboard uninterruptable power supply (UPS) ensures all samples are safely stored in the event of power disruption, maintaining the storage environment and data integrity.

Targeted and non-targeted samples are protected from warming above Tg (glass transition temperature) both in storage and during retrieval by the insulated robotic tower and intelligent software controls. Every exposure is controlled and traced to ensure samples always remain below the critical temperature.

Optional CryoPod Carriers attach to the Deca’s rim to hold samples when they are removed from the sample transport robotic tower. These award winning cryo carriers maintain sample environment temperatures at less than -150ºC for over 3 hours, depending on fill level, heat load, and lid placement. This maintains confidence in sample integrity when transporting frozen cryoboxes or cassettes or preparing to use samples at a workstation. Temperature, date, and time are logged, and users are alerted if temperature ranges are breached.

The User Experience

CryoArc Deca’s no-hassle sample placement and retrieval process and ergonomic vending machine styled design protect users from the physical stress and strain of leaning over a storage tank and also help to minimize personal protective equipment requirements.

A friendly touchscreen graphical user interface empowers users of any skill level to effortlessly manage detailed sample inventory and rapidly execute orders. User permission levels prevent accidental sample access while empowering diligent record-keeping, enabling the Deca to become a shared resource.

The Data Experience

CryoArc software uses an optional WebAPI module to seamlessly integrate with any homegrown or enterprise LIMS. In addition to smooth data flow, CryoArc Deca supports adherence to FDA 21 CFR, Part 11 requirements to satisfy regulatory demands, if required. All sample, chain-of-custody, and performance data may be downloaded in a standardized format for inclusion in audit reports.

Key Features

Easily Control and Manage the Details

Cryo critical software platforms from Azenta are vital to your cold chain management strategy.

Integrated CryoArc Software:

  • Tracks individual sample location, sample movement, and user access over the sample’s lifetime
  • Captures real-time environmental data including temperature, unexpected events, alarms, LN2 usage, and LN2 levels
  • Supports 21 CFR Part 11 compliance
  • Optional library management allows users to partition the storage space and assign access privileges to individual or groups of users
  • Optional alerts management enables custom alert configurations and notifications via email or mobile devices in response to system behavior

Remote Monitoring Portal

  • Simplifies cryo freezer maintenance across your lab or enterprise
  • Empowers real-time cryogenic storage system monitoring at any time and from anywhere in the world
  • Communicates critical at-a-glance metrics with text or email alerts if conditions change

FreezerPro Inventory Management

  • Facilitates inventory tracking, robust reporting, detailed searches, and audit trails
  • Seamlessly integrates with CryoArc Software, along with other Azenta automated storage systems and devices to enhance cold chain management convenience
  • Supports 21 CFR Part 11 compliance along with Parts 21, 58, 210,  cGLP/cGMP, and Section 508 accessibility guidelines
  • Offers high security with remote access
  • Scales to the changing needs of lower throughput labs up to large central biorepositories
Scale and Change at Your Pace

As a market-leading automated cryogenic storage system, CryoArc Deca easily adapts to your lab’s size and changing needs.

  • Accepts a wide range of labware
  • Single interface and familiar software when adding multiple units – including our smaller CryoArc Pico and larger CryoArc Tera and CryoArc Tera for Cassettes  models – to your lab or enterprise
  • Efficient space use and rapid system integration

Round out your workflows with additional high-performing Azenta cryogenic tools:

Extend Cryogenic Storage Confidence
  • Flexible Support Plans keep your CryoArc Deca investment running at peak performance
  • Trainings develop your team’s skillsets with applicable knowledge
  • Qualification Services (IQ/OQ/PQ) help you achieve compliance requirements
  • Equipment Repair, Refurbishment, or Relocation on request

 

Ensure the seamless operation of your cryogenic storage system with comprehensive Automated Cryo Storage Support Plans from Azenta.

Specifications
  CryoArc Deca -190°C LN2-Based Automated Storage System
Storage capacity 266 x 2” cryoboxes (or equivalent)
52,136 x 1.0ml Azenta cryotubes
26,600 x 2.0ml Azenta cryotubes
1,520 x 25ml cassettes
760 x 50ml cassettes
Box level retrieval speed < 60 seconds
Static holding time vapor ≥15 days